CCS CHAdeMO AC Type-2 Series

您的当前位置: 首页 > Product > DC Charger > CCS CHAdeMO AC Type-2 Series > Fast Charger 122 Kw with 3 Guns (CCS, CHAdeMO and AC Type 2) 3-in-1 Charger with 0CPP & CE Certification

Fast Charger 122 Kw with 3 Guns (CCS, CHAdeMO and AC Type 2) 3-in-1 Charger with 0CPP & CE Certification

THCCT-60/22-3:60KW CCS2.0+60KW CCS2.0+22KW AC Type-2 THCCAT-60/22-3:60KW CCS 2.0 + 60KW CHAdeMO+ 22KW AC Type-2 THGGT-60/22-3:60KW GB/T + 60KW GB/T + 22KW GB/T AC


Charging Cloud Platform
Tonhe is delicated to enabling the future of e-mobility by providing the most open, secure and robust charging network anywhere. A charging platform based on the cloud server makes it simple for charger owners to
operate and customize chargers to meet their specific requirements. We provide everything you need to offer a complete EV charging solution.
OCPP Capable: Easy process to integrate other OCPP-capable chargers to the charging cloud platform through OCPP protocol.
Real-time Monitor: A graphical dashboard shows real-time status, helping charger operator or EV driver to manage charging service from their computer or mobile phone.

Flexible Integration: Integrations with other systems - APIs allow flexible integration with other systems including payment apps, parking system, enterprise existing systetem and 3rd party cloud platform.


Charger Specification:

SpecificationModel

THCCT-60/22-3:60KW CCS2.0+60KW CCS2.0+22KW AC Type-2   THCCAT-60/22-3:60KW CCS 2.0 + 60KW CHAdeMO+ 22KW Type-2 ACTHGGT-60/22-3:60KW GB/T + 60KW GB/T + 22KW GB/T AC 

AC Nomal InputPhases/Lins3 phase+neutral+PE
Voltage400VAC±10%
Frequency50Hz±10%
ConnectorAC Type-2,CCS 2,CHAdeMO,GB/T AC,GB/T DC
OutputPowerAC Type-2:22kw,                                                       
CCS 2:60kw,                                                  CHAdeMO:60kw,                                                   
GB/T AC:22kw,                                                
GB/T DC:60kw
VolatgeAC Type-2:380-480VAC,                                      
CCS 2:200-750VDC,                                   
CHAdeMO:200-500VDC,                                        
GB/T AC:380-480VAC,                                           
GB/T DC:200-750VDC
Cable Lenth5m
Cable TypeCharging cable and connecter permanently attached to EVSE (liquid cooled)
Electrial ParameterPower Factor≥0.99,≥ 0.96 (Full Load)

THD Value≤5%
Stable Voltage Accuracy≤±0.5%
Stable Current Accuracy≤±1%
Efficiency≥95% at nominal output power
Structure DesignHousing MaterialGalvanized steel
Installation MethodVertical installation of ground
LED Indicator10 inches with 720 x 480 pixels TFT LCD Screen, user interface with touch screen or keypad.Toughened unbreakable glass to be used for display screen
ON-OFF (Start-Stop) SwitchesMandatory
Emergency Stop ButtonMushroom headed type
Payment MethodRFID CARD /Phone APP with backend
CommunicationCharegr v.s. BackendEthernet, Wi-Fi and 2G/3G/4G
Communication ProtocalOCPP1.6
Environmental             in dexWorking Temperature-20ºC-+65ºC
Storage Temperature-40ºC-+65ºC
Working Altitude≤2000M
Atmospheric pressure intensity80 kpa to 110 kpa
Application SiteIndoor/Outdoor
Cooling MethodForced air cool
Security ProtectionMultiple ProtectionOver Current, Under Current, Over Voltage, Residual Current, Surge Protection, Short Circuit, Earth Fault at input and output, Input Phase reversal, Emergency Shut-down with alarm, over temperature, Protection against electric shock.
Warranty3 years
Package InformationProduct Dimension700*600*1900(W*D*H)
Net Weight230KG
External PackingWooden case
General Requirements

Energy Transfer ModeConductive
Charging ModeCHAdeMO - mode 4 - DC Fast Charging                             
CCS 2.0 - mode 4 - DC fast charging
GB/T - mode 3 (AC) and mode 4 (DC fast charging)
Type-2 AC - mode 3
Reliability and ServiceabilityModularity, self-diagnostic features, fault codes and easy serviceability in the field
System Structure

Regulation MethodRegulated DC EV Charging Station with combination of CVC or CCC but not simultaneously
IsolationEach output isolated from each other with proper insulation
Power SupplyDC EV charging station connected to AC mains
Charge control communicationCommunicate by digital and analog signals
Interface inter-operabilityInter-operable with any EV supporting CCS or AC Type-2 (for each gun respectively)
OperatorOperated by a trained person or EV owner
Input Requirements

Input Supply Failure BackupBattery backup for minimum 1 hour for control system and billing unit, to enable activities such as billing, to be provided
Output Requirements

No. of Outputs3
Output Connectors3 output connectors
Output Connector CompatibilityAC Type 2: IEC 61851-22, IEC 62196-2 Mode 3                      
CCS: IEC 61851-23/24, IEC 62196-3, DIN 70121.               
CHAdeMO: IEC 61851-23/24, JEVS G 105, Rev. 1.2 compliant
GB/T: GB/T 20234, IEC 62196-3 (for DC) and IEC 62196-2 (for AC)
Mechanical Requirements

Mechanical StabilityShall not be damaged by mechanical impact as defined in IEC 61851-1
Mechanical ImpactShall not be damaged by mechanical impact as defined in IEC 61851-1
User Interface and Display Requirements

VisualVisual Indicators:Error indication, Presence of input supply indication, State of Charge process indication.                             
Voice notifications:Voice
Notifications: Related to start and stop of charging session in English
Support LanguageEnglish, with provision for additional regional languages
Display MessagesEVSE should display appropriate messages for user during the various charging states like:-Vehicle plugged in / Vehicle plugged out'-Duration since start of charge and kWh consumed'-User authorization status'-Fault Conditions-Metering Information: Consumption Units
Performance Requirements

DC Output Voltage and Current ToleranceDC Output current regulation in Constant Current Charging (CCC);
±2.5 A for the requirement below 50 A, and ±5% of the required value for 50 A or more DC Output voltage regulation in constant voltage charging (CVC);
Control delay of charging current in CCCDC output current demand response time1 s Ramp up rate: 20 A/s or more.Ramp Down rate: 100 A/s or more
Descending rate of charging currentEVSE should be able to reduce DC current with the descending rate of 100 A/s or more
Periodic and random deviation(Current ripple)DC Output current ripple limit of EVSE:1.5 A below 10 Hz, 6 A below 5 kHz, 9A below 150 kHz
Periodic and random deviation(Volatge ripple)Max. Ripple voltage ±5 V. Max slew rate ±20 V/ms
Billing Requirements

Software SolutionCMS and USER APP
BillingGrid Responsive metering (Billing and Metering System shall be separate for each of CCS,AC type-2 systems)
Manufacture Line:

Test Center:
Tonhe test center acquired CNAS certificate. Test center can test humidity, smoke, high and low temperature alternating, vibration and EMC and so on, which can assure product reliability and make performance more complete and professional.

【返回列表】

上一个产品: 4 in 1 Control Unit

下一个产品: 暂无下一篇

Link : ANHUI TONHE NEW ENERGY TECHNOLOGY

Address:2-1 LIANDONG U VALLEY, SHENZHEN RD CROSS PENGLAI ROAD, HEFEI CITY, ANHUI PROVINCE CHINA     

Service hotline:86 0551 62936742

Email:tonghetechsales@outlook.com    Mobile: 86 18019953959